                                                         ANNEX II
                                    Ecodesign requirements for non-directional household lamps


         1. LAMP EFFICACY REQUIREMENTS
         Incandescent  lamps  with  S14,  S15  or  S19  caps  shall  be  exempted  from  the  efficacy
         requirements of Stages 1 to 4 as defined in Article 3 of this Regulation, but not from Stages 5
         and 6. The maximum rated power (P max  ) for max a given rated luminous flux ( ø ) is provided in
         Table 1. The exceptions to these requirements are listed in Table 2 and the correction factors
         applicable to the maximum rated power are in Table 3.



                                                           TABLE 1
                                                    Maximum rated power (P  ) for a given rated luminous flux ( ) (W)
                                 Application date                   max
                                                        Clear lamps           Non-clear lamps
                                  Stages 1 to 5     0.8* (o,88 √ ø + 0,049 ø)  0.24 √ ø + 0,0103 ø
                                   Stage 6          0.6* (o,88 √ ø + 0,049 ø)  0.24 √ ø + 0,0103 ø



                                                       TABLE 2 - EXCEPTIONS
                                    Scope of the exception            Maximum rated power (w)
                              Clear lamps 60 lm ≤ ø ≥ 950 lm in Stage1  P  = 1,1* (0,88 √ ø + 0,049 ø)
                                                                     max
                              Clear lamps 60 lm ≤ ø ≥ 725 lm in Stage2  P max   = 1,1* (0,88 √ ø + 0,049 ø)
                              Clear lamps 60 lm ≤ ø ≥ 450 lm in Stage3  P max   = 1,1* (0,88 √ ø + 0,049 ø)
                              Clear lamps with G9 or R7s cap in Stage6  P max   = 0,8* (0,88 √ ø + 0,049 ø)
                              The correction factors in Table 3 are cumulative where appropriate and also applicable to the products covered by the exceptions of Table 2.



                                                    TABLE 3 - CORRECTION FACTORS
                                                                                     Maximum rated
                                                 Scope of correction
                                                                                       power (w)
                                        Filament lamp requiring external power supply  P max   /1,06
                                             Discharge lamp with cap GX53              P  /0,75
                                                                                        max
                              non-clear lamp with colour rendering index ≥ 90 and P ≤ 0,5* (0,88 √ ø + 0,049 ø)   P  /0,85
                                                                                        max
                                   Discharge lamp with colour rendering index ≥ 90 and Tc ≥ 5000 K  P  /0,76
                                                                                        max
                                 non-clear lamp with second envelope and P ≤ 0,5* (0,88 √ ø + 0,049 ø)  P max   /0,95
                                          Led lamp requiring external power supply     P max   /1,1



         2. LAMP FUNCTIONALITY REQUIREMENTS
         The lamp functionality requirements are set out in Table 4 for compact fluorescent lamps and
         in Table 5 for lamps excluding compact fluorescent lamps and LED lamps.
         Where the rated lamp lifetime is higher than 2 000 h, the Stage 1 requirements for the
         parameters Rated lamp lifetime,Lamp Survival Factor and Lumen maintenance in Tables 4 and
         5 are only applicable as from Stage 2.
         For the purposes of testing the number of times the lamp can be switched on and off before
         failure, the switching cycle shall consist of periods comprising 1 minute on and 3 minutes off,
         while the other test conditions are defined according to Annex III. For the purposes of testing
         lamp lifetime, lamp survival factor, lumen maintenance and premature failure, the standard
         switching cycle according to Annex III shall be used.


                                        TABLE 4 - FUNCTIONALITY REQUIREMENTS FOR COMPACT FLUORESCENT LAMPS
                             Functionality parameter      Stage 1                 Stage 5
                           Lamp survival factor at 6000h  ≥ 0,50                  ≥ 0,70
                                                                              At 2 000 h: ≥ 88 %
                                                At 2000 h: ≥ 85% (≥ 80% for a lamps   ( ≥ 83 % for lamps
                               Lumen maintenanc
                                                   with second lamp envelope)  with second lamp envelope)
                                                                              At 6 000 h: ≥ 70 %
                                                 ≥ half the lamp lifetime expressed
                            Number of switching cycles   in hours        ≥ lamp lifetime expressed in hours
                                 before failure    ≥ 10 000 if lamp starting time  ≥ 30 000 if lamp starting time > 0,3 s
                                                          > 0,3 s