Page 7 - DAYLIGHT ITALIA 2020
P. 7

5    DAYLIGHTITALIA



                                                                              <1,5 s if P < 10W
                                Starting time            <2,0 s
                                                                               <1,0 if P ≥ 10W
                                               < 60 s or < 120 s for lamps containing   < 40 s or < 100 s for lamps contai-
                           Lamp warm-up time to 60% ø
                                                   mercury in amalgam form  ning mercury in amalgam form
                             Premature failure rate   ≤ 2,0 % at 200 h        ≤ 2,0 % at 400 h
                              UVA + UVB radiation      ≤ 2,0 mW/klm            ≤ 2,0 mW/klm
                                UVC radiation          ≤ 0,01 mW/klm           ≤ 0,01 mW/klm
                                                      ≥ 0,50 if P < 25 W      ≥ 0,55 if P < 25 W
                              Lamp power factor
                                                      ≥ 0,90 if P ≥ 25 W      ≥ 0,90 if P ≥ 25 W
                             Colour rendering (Ra)        ≥ 80                    ≥ 80

                              TABLE 5 - FUNCTIONALITY REQUIREMENTS FOR LAMPS EXCLUDING COMPACT FLUORESCENT LAMPS AND LED LAMPS
                             Functionality parameter     Stage 1                 Stage 5

                                                 ≥ 85 % at 75 % of rated average  ≥ 85 % at 75 % of rated average
                              Lumen maintenance
                                                         lifetime                lifetime
                              Rated lamp lifetime       ≥ 1 000 h                ≥ 2 000 h
                                                  ≥ four times the rated lamp life  ≥ four times the rated lamp life
                            Number of switching cycles
                                                     expressed in hours       expressed in hours
                               Star t in g t ime         < 0,2 s                  < 0 ,2 s
                           Lamp warm-up time to 60 % ø   ≤ 1,0 s                  ≤ 1,0 s
                             Premature failure rate   ≤ 5,0 % at 100 h         ≤ 5,0 % at 200 h
                              UVA + UVB radiation      ≤ 2,0 mW/klm            ≤ 2,0 mW/klm
                                UVC radiation          ≤ 0,01 mW/klm           ≤ 0,01 mW/klm
                              Lamp power factor          ≥ 0,95                   ≥ 0,95


          3.    PRODUCT INFORMATION REQUIREMENTS ON LAMPS     (e)   Warm-up time up to 60 % of the full light output (may be indicated as instant full light if
             For non-directional household lamps, the following information shall be provided     less than 1 second);
             as from Stage 2, except where otherwise stipulated.  (f)   A warning if the lamp cannot be dimmed or can be dimmed only on specific dimmers;
          3.1.   Information to be visibly displayed prior to purchase to end-users on the packaging and    (g)   If designed for optimal use in non-standard conditions (such as ambient temperature Ta
             on free access websites.                            ≠25 °C), information on those conditions;
             The information does not need to be specified using the exact wording of the list below.    (h)   Lamp dimensions in millimeters (length and diameter);
             It may be displayed using graphs, figures or symbols rather than text.  (i)    If equivalence with an incandescent lamp is claimed on the packaging, the claimed
             These information requirements do not apply to filament lamps not fulfilling the efficacy      equivalent incandescent lamp power (rounded to 1 W) shall be that corresponding in
             requirements of Stage 4.                            Table 6 to the luminous flux of the lamp contained in the packaging.
          (a)   When the nominal lamp power is displayed outside the energy label in accordance with       The intermediate values of both the luminous flux and the claimed incandescent lamp
             Directive 98/11/EC, the nominal luminous flux of the lamp shall also be separately       power (rounded to 1W) shall be calculated by linear interpolation between the two
             displayed in a font at least twice as large as the nominal lamp power display outside the       adjacent values.
            label;
          (b)   Nominal life time of the lamp in hours (not higher than the rated life time);
          (c)   Number of switching cycles before premature lamp failure;
          (d)   Colour temperature (also expressed as a value in Kelvins);
                                                          TABLE 6
                                                                              Claimed equivalent
                                          Functionality parameter
                                                                            incandescent lamp power
                                 CFL            Halogen    LED and other lamps     (W)
                                 125             119            136                 15
                                 229             217            249                 25
                                 432             410            470                 40
                                 741             702            806                 60
                                 970             920            1055                75
                                 1398            1326           1521               100
                                 2253            2137           2452               150
                                 3172            3009           3452               200

          (j)   The term energy saving lamp or any similar product related promotional statement about   (b)  Rated wattage (0,1 W precision);
             lamp efficacy may only be used if the lamp complies with the efficacy requirements    (c)   Rated luminous flux;
             applicable to non-clear lamps in Stage 1 according to Tables 1, 2 and 3. If the lamp    (d)   Rated lamp life time;
             contains mercury                                 (e)   Lamp power factor;
          (k)   Lamp mercury content as X,X mg;               (f)   Lumen maintenance factor at the end of the nominal life;
          (l)    Indication which website to consult in case of accidental lamp breakage to find    (g)   Starting time (as X,X seconds);
             instructions on how to clean up the lamp debris.  (h)  Colour rendering. If the lamp contains mercury
          3.2.  Information to be made publicly available on free-access websites  (i)    Instructions on how to clean up the lamp debris in case of accidental lamp breakage;
             As a minimum, the following information shall be expressed at least as values.  (j)   Recommendations on how to dispose of the lamp at its end of life.
          (a)   The information specified in point 3.1;
   2   3   4   5   6   7   8   9   10   11   12