Page 8 - DAYLIGHT ITALIA 2020
P. 8

DAYLIGHTITALIA   6

                                                         ANNEX III
                                      Verification procedure for market surveillance purposes

         Member State authorities shall test a sample batch of minimum 20 lamps of the same model   States shall use accurate and reliable state-of-the-art measurement methods which deliver
         from the same manufacturer randomly selected.        reproducible results, including:
         The batch shall be considered to comply with the provisions set out in Annex II as applicable,   - where available, harmonised standards the reference numbers of which have been published
         of this Regulation if the average results of the batch do not vary from the limit, threshold or   for that purpose in the Official Journal of the European Union in accordance with Articles 9 and
         declared values by more than 10 %.                   10 of Directive 2005/32/EC,
         Otherwise, the model shall be considered not to comply.  - otherwise, the methods set out in the following documents:
         For the purposes of checking conformity with the requirements, the authorities of the Member




                           Measured parameter  Organisation(1)  Reference        Title
                                                                      Commission Decision 2002/747/EC of
                                                                      9 September 2002 establishing revised
                             Lamp mercury    European      Decision   ecological criteria for the award of the
                               content      Commission  2002/747/EC (Annex)
                                                                      Community ecolabel to light bulbs and
                                                                      amending Decision 1999/568/EC
                                                                      Energy efficiency of electric lamps for
                            Luminous efficacy  Cenelec   EN 50285:1999
                                                                      household use—Measurement methods
                                                         EN 60061:1993  Lamp caps and holders together with
                              Lamp caps      Cenelec     All amendments  gauges for the control of interchangea-
                                                         up to A40:2008  bility and safety Part 1: Lamp caps
                                                         EN 60064:1995
                                                          Amendments
                                                           A2:2003    Tungsten filament lamps for domestic
                                             Cenelec                  and similar general lighting purposes -
                                                           A3:2006    Performance requirements
                                                           A4:2007
                                                           All:2007
                             Lamp lifetime               EN 60357:2003  Tungsten halogen lamps (non-vehicle)-
                                             Cenelec      Amendment   Performance specifications
                                                           Al:2008
                                                         EN 60969:1993  Self-ballasted lamps for general lighting
                                                          Amendments
                                             Cenelec                  services
                                                           Al:1993
                                                           A2:2000    - Performance requirements
                                                         EN 60969:1993  Self-ballasted lamps for general lighting
                            Lamp start time/  Cenelec     Amendments  services
                              warmup time                  Al:1993    - Performance requirements
                                                           A2:2000




                           Measured parameter  Organisation(1)  Reference        Title

                                                                       Electromagnetic compatibility (EMC)
                                                                                Part 3-2:
                              Power factor   Cenelec    EN 61000-3-2:2006  Limits - Limits for harmonic current
                                                                       emissions (equipment input current ≤
                                                                              16 A per phase)
                            Specific effective  Cenelec  EN 62471:2003  Photobiological safety of lamps and
                            radiant UV power                                  lamp systems
                                            International              Method of Measuring and Specifying
                            Colour rendering  Commission on  CIE 13.3:1995       Colour
                                            Illumination               Rendering Properties of Light Sources
                              Chromaticity  International
                            Correlated Colour  Commission on  CIE 15:2004      Colorimetry
                           Temperature (Tc [K])  Illumination
                                            International
                              Luminance    Commission on  CIE 18.2:1983  The Basis of Physical Photometry
                                            Illumination

                                            International
                             Luminous flux  Commission on  CIE 84:1989  The Measurement of Luminous Flux
                                            Illumination
                              Lamp Lumen
                              Maintenance   International              Maintenance of indoor electric lighting
                              Factor(LLMF)  Commission on  CIE 97:2005
                             Lamp Survival  Illumination                        systems
                              Factor (LSF)