Page 8 - DAYLIGHT ITALIA 2020
P. 8
DAYLIGHTITALIA 6
ANNEX III
Verification procedure for market surveillance purposes
Member State authorities shall test a sample batch of minimum 20 lamps of the same model States shall use accurate and reliable state-of-the-art measurement methods which deliver
from the same manufacturer randomly selected. reproducible results, including:
The batch shall be considered to comply with the provisions set out in Annex II as applicable, - where available, harmonised standards the reference numbers of which have been published
of this Regulation if the average results of the batch do not vary from the limit, threshold or for that purpose in the Official Journal of the European Union in accordance with Articles 9 and
declared values by more than 10 %. 10 of Directive 2005/32/EC,
Otherwise, the model shall be considered not to comply. - otherwise, the methods set out in the following documents:
For the purposes of checking conformity with the requirements, the authorities of the Member
Measured parameter Organisation(1) Reference Title
Commission Decision 2002/747/EC of
9 September 2002 establishing revised
Lamp mercury European Decision ecological criteria for the award of the
content Commission 2002/747/EC (Annex)
Community ecolabel to light bulbs and
amending Decision 1999/568/EC
Energy efficiency of electric lamps for
Luminous efficacy Cenelec EN 50285:1999
household use—Measurement methods
EN 60061:1993 Lamp caps and holders together with
Lamp caps Cenelec All amendments gauges for the control of interchangea-
up to A40:2008 bility and safety Part 1: Lamp caps
EN 60064:1995
Amendments
A2:2003 Tungsten filament lamps for domestic
Cenelec and similar general lighting purposes -
A3:2006 Performance requirements
A4:2007
All:2007
Lamp lifetime EN 60357:2003 Tungsten halogen lamps (non-vehicle)-
Cenelec Amendment Performance specifications
Al:2008
EN 60969:1993 Self-ballasted lamps for general lighting
Amendments
Cenelec services
Al:1993
A2:2000 - Performance requirements
EN 60969:1993 Self-ballasted lamps for general lighting
Lamp start time/ Cenelec Amendments services
warmup time Al:1993 - Performance requirements
A2:2000
Measured parameter Organisation(1) Reference Title
Electromagnetic compatibility (EMC)
Part 3-2:
Power factor Cenelec EN 61000-3-2:2006 Limits - Limits for harmonic current
emissions (equipment input current ≤
16 A per phase)
Specific effective Cenelec EN 62471:2003 Photobiological safety of lamps and
radiant UV power lamp systems
International Method of Measuring and Specifying
Colour rendering Commission on CIE 13.3:1995 Colour
Illumination Rendering Properties of Light Sources
Chromaticity International
Correlated Colour Commission on CIE 15:2004 Colorimetry
Temperature (Tc [K]) Illumination
International
Luminance Commission on CIE 18.2:1983 The Basis of Physical Photometry
Illumination
International
Luminous flux Commission on CIE 84:1989 The Measurement of Luminous Flux
Illumination
Lamp Lumen
Maintenance International Maintenance of indoor electric lighting
Factor(LLMF) Commission on CIE 97:2005
Lamp Survival Illumination systems
Factor (LSF)